Mag610/611
Three-axis fluxgate magnetometers operable at up to 215°C, designed to survive high levels of shock and vibration.
Typed specifications35 values
Discloses 8 of 11 fields engineers filter by in this category (category median 8).
- Mass
- 25 g Mag610/Mag611 probe, with 1m wires · datasheet p.5 25 g with 1m wires
- Measurement range
- 100 µT Mag610/611 RTPDE/RTUDE drive electronics, ±100uT when calibra… · datasheet p.7
- Envelope (L×W×H)
- 23 x 23 x 21.4mm datasheet p.5 Ø26x114 mm Mag610/611 RTPDE electronics | 19.3x73 mm Mag610/611 RTUDE electronics | 23 x 23 x 21.4mm (WxHxL) Mag610/Mag611 probe
- Output data rate
- 15 625 Hz product page
- Noise density
- 0.3 nT/√Hz max · Mag610/Mag611, at 1Hz, over full temperature range · datasheet p.4
- Supply voltage
- 12–15 V Mag610/611 RTPDE/RTUDE supply, ±12V to ±15V · datasheet p.7
- Operating temperature
- 0 °C min · datasheet p.5 -98.2 °C max · Mag610 | -58.2 °C max · Mag611 | 0–175 °C Mag610 | -40–70 °C Mag610/611 RTPDE/RTUDE electronics +1
- Sensor type
- fluxgate datasheet p.2
- Axes
- 3 three (right hand XYZ co-ordinate system) · datasheet p.4
- Output type
- analog Mag610/611 RTPDE/RTUDE, ±10V unbalanced single ended · datasheet p.7
- Connector
- RM15-TPD-10P (when supplied with Mag610/611 RTPDE) datasheet p.5
- Survival temperature
- 0 °C min · datasheet p.5 -98.2 °C max · Mag610 | -58.2 °C max · Mag611 | 0–175 °C storage, Mag610 | -40–70 °C storage, Mag610/611 RTPDE/RTUDE electronics +1
- Shock qualification
- 150 g mechanical shock 1.3ms 150G peak · datasheet p.5 150 g peak shock
- Intended use
- other magnetic ranging, measurement while drilling (MWD), applicati… · datasheet p.3
- Configuration
- separate sensor head probe with separate room temperature drive electronics · datasheet p.6
- Zero offset
- 1 000 nT at 215°C, scaled for 100μT range electronics · datasheet p.4 500 nT max · at 25°C, scaled for 100μT range electronics
- Axis orthogonality error
- 2 ° max · orthogonality error <2°, Mag610/Mag611 · datasheet p.4
- Bandwidth
- 500 Hz min · Mag610/611 RTPDE/RTUDE, bandwidth (-3dB) · datasheet p.7 100 Hz min · Mag610/Mag611 probe, bandwidth (-3dB) >100Hz
Each value is typed with its unit and measurement condition and cites the datasheet page it was taken from. Nothing is guessed: a field that is absent here has not been published by the manufacturer. machine-extracted ✓ checked by NewSpace Market ✓ manufacturer confirmed by the manufacturer.
As published by the supplier16 lines, in the manufacturer's own wording
- Operating temperature
- 0°C to +175°C
- Bandwidth
- >100 Hz
- Measurement noise floor
- ≤300pTrms /√Hz at 1 Hz
- Output scaling
- 113µT/mA typical
- Scaling error
- ±5% at 25°C
- Scaling temperature coefficient
- <+150ppm/°C
- Offset
- ±500nT max. at 25°C
- Offset temperature coefficient
- <±1nT/°C
- Orthogonality error
- <2°
- Alignment error to enclosure side
- <2°
- Frequency response
- <1% amplitude error DC to 10 Hz
- Hysteresis
- <0.1% of range
- Storage temperature
- 0°C to +175°C
- Dimensions
- 23 x 23 x 21.4 mm
- Weight
- 25 g
- Recommended excitation frequency
- 15.625 kHz
About
The Mag610 and Mag611 are compact three-axis fluxgate magnetometers capable of operating at extreme temperatures. The Mag610 can function up to 175°C, while the Mag611 extends this capability to 215°C. These magnetometers are engineered for resilience, designed to withstand high levels of shock and vibration, making them particularly suitable for demanding environments. Their robust design and high-temperature operation make them ideal for applications such as measurement while drilling (MWD) and magnetic ranging. The compact probe heads are available in different sizes, facilitating easy integration into various systems. Key applications include drill navigation during MWD, magnetic ranging in oil and gas production, and any scenario requiring high shock and temperature resistance.
Documentation
- DS3629.pdf PDF source: www.bartingtondownloads.com ↗
- OM3223.pdf PDF source: www.bartingtondownloads.com ↗
- AN0050.pdf PDF source: www.bartingtondownloads.com ↗
Need the full ICD, test reports or a specific revision? Ask the supplier directly.