Mag639
This wide bandwidth fluxgate magnetometer offers measurements from DC to 12kHz of field strengths up to ±100μT, featuring a non-conductive cylindrical enclosure to prevent eddy currents.
Typed specifications18 values
Discloses 8 of 11 fields engineers filter by in this category (category median 8).
- Mass
- 300 g datasheet p.5
- Measurement range
- 100 µT ±100μT · datasheet p.4 100 µT max
- Envelope (L×W×H)
- 28.1 (Ø) x 218mm (L) datasheet p.5
- Output data rate
- 12 000 Hz max · datasheet p.3
- Noise density
- 0.02 nT/√Hz max · measurement noise floor at 1Hz · datasheet p.4
- Supply voltage
- 15–17 V ± · datasheet p.5 15–17 V ±15V to ±17V
- Operating temperature
- -20–70 °C datasheet p.4
- Sensor type
- fluxgate wide bandwidth fluxgate sensor · datasheet p.2
- Axes
- 3 datasheet p.4
- Output type
- analog ±10V unbalanced single ended · datasheet p.5
- Connector
- Hirose RM15TRD10S datasheet p.5
- Intended use
- ground or laboratory TDEM, magnetotellurics, EMC interference measurement, UXO det… · datasheet p.3
- Configuration
- integrated (sensor + electronics) single cylindrical enclosure with integral cable · datasheet p.5
- Zero offset
- 50 nT max · offset error · datasheet p.4
- Axis orthogonality error
- 0.5 ° max · datasheet p.4
- Bandwidth
- 12 000 Hz -3dB, 0 to 12kHz (±5%) at 50% full scale · datasheet p.4
Each value is typed with its unit and measurement condition and cites the datasheet page it was taken from. Nothing is guessed: a field that is absent here has not been published by the manufacturer. machine-extracted ✓ checked by NewSpace Market ✓ manufacturer confirmed by the manufacturer.
As published by the supplier14 lines, in the manufacturer's own wording
- Bandwidth
- DC to 12 kHz
- Noise level
- <20pTrms/√Hz at 1 Hz
- Measuring range
- ±100µT
- Environmental sealing
- IP65
- Offset error
- <50nT
- Scaling error
- ±0.5%
- Orthogonality error
- <0.5°
- Frequency response
- DC-5 kHz (±5%)
- Hysteresis
- <5nT at 100μT
- Operating temperature
- -20°C to 70°C
- Dimensions
- 28.1 x 218 mm
- Mass
- 300 g
- Supply voltage
- ± 15 V to ± 17 V
- Interface
- ±10 V (unbalanced, single ended ref. 0 V)
About
The Mag639 is a wide bandwidth three-axis fluxgate magnetometer designed for precise magnetic field measurements. It is capable of measuring field strengths up to ±100μT across a frequency range from DC to 12kHz. The device incorporates a non-conductive cylindrical enclosure, which effectively prevents the creation of eddy currents, ensuring accurate readings. A 2.5m shielded cable is integrated to position the sensor connector away from the fluxgates, further enhancing measurement integrity. The magnetometer features three concurrent fluxgate elements, which are crucial for minimising the impact of high magnetic field gradients. Key features include a wide bandwidth from DC to 12kHz, a low noise level of <20pTrms/√Hz at 1Hz, and a ±100µT measuring range. The concurrent axes ensure a single point of intersection for measurements, and the unit is environmentally sealed to IP65 for robust performance in various conditions. Applications for the Mag639 include Time-domain electromagnetics (TDEM), Magnetotellurics (MT), EMC Interferences measurement, and Unexploded ordnance (UXO) detection.
Documentation
- DS2240.pdf PDF source: bartingtondownloads.com ↗
- OM2240.pdf PDF source: www.bartingtondownloads.com ↗
- AN0019.pdf PDF source: www.bartingtondownloads.com ↗
Need the full ICD, test reports or a specific revision? Ask the supplier directly.