Block Up-Converter (BUC) — RGUC-D Mid Power, frequency S: 17.3-18.1 GHz E: 18.1-18.4 GHz, output 20W, 40W.
Key figurescomparable across the catalogue
- Mass
- 3.27 kg
- Power
- 20 W
- Largest dimension
- 205.99 mm
Normalised to common units so this product can be compared with others in its category. The supplier's own wording is below.
As published by the supplier
- Frequency
- S: 17.3-18.1 GHz E: 18.1-18.4 GHz
- Power/output
- 20 W, 40 W
- RF frequency
- 17.3-18.GHz 18.1-18.4 GHz
- If frequency
- 950-1750 MHz 1150-1450 MHz
- Local frequency
- 16.35 GHz 16.95 GHz
- External ref
- 10 MHz, 0±5 dBm
- Output power
- 20 W 40 W
- Rated/saturated
- 43 dBm 46 dBm
- Plin1
- 42 dBm 45 dBm
- Plin2
- 41 dBm 44 dBm
- Plin3
- 40 dBm 43 dBm
- Small signal gain
- 70 dB
- Gain variation
- 0.25 dB p-p/1 MHz
- Gain stability
- 3 dB p-p
- Gain adjustment
- 20 dB (Step: 0.5 dB)
- Phase noise
- -62 dBc/Hz@100 Hz
- Output spurious
- -55 dBc
- R g u c - d a b b -
- 4 8 R E
- Input power
- +36 to +72 vDC
- Power consumption
- 20 W 40 W
- RF output vswr
- 1.25:1
- If input vswr
- 1.5:1
- Dimensions
- 8.11*5.35*3.47 inches
- Mass
- 7.2 7.7 lbs
- Operating temperature
- -40 to +60oC
- Humidity
- 0-100% (condensing)
- Altitude
- 0-10,000 feet ASL
About
RevGo Global’s RGUC-D Mid Power is a block up-converter (buc) designed for satellite ground-segment (VSAT/SNG/maritime) RF chains, manufactured by RevGo Global Inc. (Reston, VA, USA), a satellite earth-station RF equipment manufacturer founded in 2002 and operating an ISO 9001:2015 quality system. This model operates over S: 17.3-18.1 GHz E: 18.1-18.4 GHz with rated output/class of 20W, 40W. RevGo’s product line uses highly integrated RF technologies (RFIC and GaN), is designed for high-volume production, and is built for rugged outdoor operation (typ. -40 to +60C, 0-100% humidity condensing, up to 10,000 ft altitude). Typical applications include maritime VSAT terminals, 5G backhaul, SNG (satellite news gathering) vehicles, and fixed, portable, or transportable satellite terminals. Full RF, power, mechanical, and interface specifications are provided in the manufacturer’s datasheet linked below.
Documentation