IVK-01N Complex
Spacecraft automated electrical test complex (Ethernet/MIL-STD-1553B, 29-ch pulse + 18-ch long-term command outputs, 67-ch on-off monitoring, magnetic field simulation, QNX/Windows). Customizable.
Technical specifications
- Purpose
- Automated spacecraft technical condition testing and routine maintenance
- Year of release
- 2016
- Guaranteed service life, years
- 10
- Estimated production/delivery time
- 12 months
- Customization
- Can be adapted to customer requirements
- Galvanic isolation
- Opto-relay or mechanical relay
- Communication interfaces
- Ethernet, MIL-STD-1553B
- DC supply
- 24–31 V, 5 A (programmable)
- Pulse command output
- 24–31 V, 0.1–0.2 s, up to 4 A, 29 channels
- Long-term command output
- 24–31 V, up to 0.5 A, 18 channels
- On-off signal monitoring
- Up to 32 V, 100 mA, 67 channels
- Analog voltage measurement
- 0–40 V, 21 channels, 1% error
- Magnetic field simulation/compensation
- ±10 V, 6 channels
- Insulation resistance monitoring
- Live busbars vs. housing
- Software
- QNX, Windows OS, specialized test software
- UPS
- Yes
- TRL
- 9
About
The IVK-01N Complex automates determination of spacecraft technical condition by simulating input actions, control signals, and tolerance checking of parameters at the manufacturer, technical complex, and launch complex, as well as routine maintenance. Features: galvanic isolation (opto-relay or mechanical relay), Ethernet and MIL-STD-1553B interfaces, programmable 24–31 V / 5 A DC supply, 29-channel pulse command output (24–31 V, 0.1–0.2 s, up to 4 A), 18-channel long-term command output (24–31 V, up to 0.5 A), 67-channel on-off signal monitoring (up to 32 V, 100 mA), 21-channel analog voltage measurement (0–40 V, 1% error), 6-channel Earth magnetic field simulation/compensation (±10 V), live busbar insulation resistance monitoring, UPS. Software: QNX, Windows OS, specialized test software. Contains industrial computer, spacecraft interfacing device, cross-switch, and product simulator. Released 2016, 10-year life, 12-month delivery. Customizable.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.