Gradiometer (MFG-2S)
Dual-sensor fluxgate gradiometer for detecting small-scale magnetic field anomalies and spacecraft magnetic moment testing.
Technical specifications
- Sensor configuration
- Two independent fluxgate sensors in spatial gradient arrangement
- Measurement type
- Magnetic field gradient / anomaly detection
- Primary use
- Spacecraft magnetic moment determination, magnetic cleanliness testing
- Known users
- ESTEC (ESA), Thales Alenia Space
- Base sensor noise
- < 15 pT/sqrt(Hz) @ 1 Hz (per Magson fluxgate sensor design)
About
The Magson Gradiometer (MFG-2S) measures the magnetic field gradient using a spatial arrangement of two independent Magson fluxgate sensors. This dual-sensor setup is specifically used to detect small-scale anomalies in the ambient magnetic field by comparing readings between the two spatially separated sensors, canceling out uniform background field contributions while isolating localized gradients. The gradiometer is used for magnetic moment determination and magnetic cleanliness testing of spacecraft components at facilities including ESTEC (the European Space Agency’s technology center) and Thales Alenia Space, making it a valuable tool for satellite AIT (assembly, integration, and test) magnetic compatibility campaigns as well as terrestrial geophysical anomaly detection surveys.
Documentation
- MFG-2S_short_data_sheet.pdf PDF source: www.magson.de ↗
- MFG-2S-LC_short_data_sheet.pdf PDF source: www.magson.de ↗
Need the full ICD, test reports or a specific revision? Ask the supplier directly.