Mechanical Unit of Antenna Pointing System. Type 1
2-DOF electromechanical antenna pointing drive (±25° per axis, 65 N·m, 150 kg·m² load inertia, 10-year life).
Technical specifications
- Purpose
- Rotation of antenna mounting plane in two mutually perpendicular planes
- Estimated production/delivery time
- 6 months
- Rotation angle per axis, °
- ±25
- Slew rate, °/min
- 0.009–7.0
- Measurement error per axis (arcsec), not exceeding
- 90
- Developed torque per axis (N·m), not less than
- 65
- Load inertia moment (kg·m²), not exceeding
- 150
- Self-braking torque (de-energized, per axis, N·m), not less than
- 6
- Operating temperature range, °C
- -50 to +50
- Operational life (hours), not less than
- 44,000
- Active lifetime, years
- 10
- Overall guaranteed lifetime, years
- 14
- TRL
- 9
About
The Mechanical Unit of Antenna Pointing System Type 1 provides rotation of the antenna mounting plane relative to the antenna pointing system control module in two mutually perpendicular planes. It is a two-degree-of-freedom electromechanical drive for antenna pointing with a slew rate of 0.009–7.0 °/min per axis and minimum torque of 65 N·m, supporting load inertia up to 150 kg·m². The self-braking torque in de-energized state is at least 6 N·m per axis. Designed for 44,000+ hours operational life, 10-year active lifetime, and 14-year overall guaranteed lifetime. Delivery time 6 months.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.