Pumping Station
An explosion-proof pumping station with a submersible pump that supplies hydraulic fluid (oil) at specified pressure, filtration, and flow rate to closed-loop hydraulic systems used in launch ground infrastructure.
Key figurescomparable across the catalogue
- Power
- 35,500 W
- Design life
- 10 years
- Lead time
- 18 months
Normalised to common units so this product can be compared with others in its category. The supplier's own wording is below.
As published by the supplier
- Working fluid
- Oil MGE-10A TU 38.401-58-337-2003 Purity class not lower than 10 by GOST 17126-71
- Ambient temperature
- +5 to +35°C
- Nominal pressure
- 50 to 400 (kgf/cm2)
- Pump power consumption at 1000 rpm of electric motor shaft
- Up to 35.5 kW
- Tank capacity
- More than 15 l
- Vibration protection
- Yes
- Year of release
- 2014
- Design life
- 10 years
- Lead time
- 18 months
- Flight qualification of the product
- No
- Possibility to adapt the product to customer requirements
- Yes
About
The Pumping Station is designed to supply hydraulic fluid (oil) with specified parameters — pressure, filtration degree, and flow rate — into closed-loop hydraulic systems. It is intended for use indoors or in environments with high requirements for explosion safety, making it suitable for cosmodrome/launch ground infrastructure applications. The unit is built as an explosion-proof pumping station with a submersible pump. It uses working fluid Oil MGE-10A (TU 38.401-58-337-2003) with a purity class not lower than 10 per GOST 17126-71, and operates within an ambient temperature range of +5 to +35°C. It provides a nominal pressure range of 50 to 400 kgf/cm2, with pump power consumption of up to 35.5 kW at 1000 rpm of the electric motor shaft, and a tank capacity of more than 15 liters. The station includes vibration protection. It was released in 2014, has a guaranteed service life of 10 years, and an estimated production/delivery time of 18 months. The product is not flight-qualified and can be adapted to customer requirements.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.