Radiation Hard Vidicon LI501-1MK
The Radiation Hard Vidicon LI501-1MK is a radiation-hardened vidicon camera tube designed for TV cameras operating in high radiation environments up to 5·10^7 rad, featuring magnetic focusing and electrostatic deflection.
Key figurescomparable across the catalogue
- Mass
- 0.018 kg
- Design life
- 4 years
- Lead time
- 2 months
Normalised to common units so this product can be compared with others in its category. The supplier's own wording is below.
As published by the supplier
- Purpose
- TV cameras in conditions of high radiation up to 5·107 rad.
- Year of release
- 2009
- Design life
- 4 years
- Lead time
- 2 months
- Flight qualification of the product
- No
- Possibility to adapt the product to customer requirements
- Yes
- Target active area
- 6.6×8.8 mm
- Length
- ≤90 mm
- Mass
- ≤18 g
- Heater voltage
- 6.3 V
- Signal current
- ≥0.15 μA
- Resolution at the center
- ≥600 TVL
- Resolution in the corners
- ≥550 TVL
- Modulation depth at 400 tvl (at the center)
- ≥55 %
- Dark current
- ≤0.003 μA
- Guaranteed life
- 1000 h
About
The Radiation Hard Vidicon LI501-1MK is a specialized camera tube engineered for use in TV cameras that must operate reliably in conditions of high radiation, specifically up to 5·10^7 rad. This vidicon, released in 2009, has a guaranteed service life of 4 years and an estimated production/delivery time of 2 months. Its target is based on CdSe and it utilizes magnetic focusing and electrostatic deflection. While it does not have flight qualification, there is a possibility to adapt the product to customer requirements. Key performance specifications include a target active area of 6.6×8.8 mm, a maximum length of 90 mm, and a mass of 18 g. It operates with a heater voltage of 6.3 V, produces a signal current of at least 0.15 μA, and boasts a resolution of at least 600 TVL at the center and 550 TVL in the corners. The modulation depth at 400 TVL (at the center) is at least 55%, with a dark current of no more than 0.003 μA. The guaranteed operational life is 1000 hours.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.