HARDWARE / PRODUCT

GaN X SSPA 300W Indoor

TTI Norte
GaN X SSPA 300W Indoor

An indoor 300W GaN X-band SSPA for commercial, government, and defense SATCOM, featuring high power, efficiency, and robust performance.

Key figurescomparable across the catalogue

Mass
23 kg
Power
800 W
Largest dimension
684 mm

Normalised to common units so this product can be compared with others in its category. The supplier's own wording is below.

As published by the supplier

Output power (PSAT (typical))
55 dBm
Output power (PLINEAR (typical))
52 dBm
Input voltage
90-264 VAC, 50-60 Hz
Power consumption @ PSAT
800 W
Dimensions (W x H x D) - RF unit (air cooling)
483 x 266 x 560 mm - 6RU panel height
Dimensions (W x H x D) - (water cooling)
343 x 120 x 508 mm - 343 x 120 x 684 mm with pipes
Weight
<23 kg
Operating temperature
0 ºC to +50 ºC
Storage temperature
-40 ºC to +85 ºC
Operating frequency range
7.9 - 8.4 GHz
3rd order IMD (2 tones 5 MHz apart*)
-25 dBc @PLINEAR
Gain @ PSAT
>60 dB
Gain flatness
±1.0 dB p-p max
Gain stability over 24 hours
±0.25 dB @ constant temperature and drive level
Gain variation over temperature
±1.5 dB over the whole range
Attenuation adjustment range
20 dB whit in 0.1 dB steps
Input VSWR
<1.3:1
Output VSWR
<1.3:1
Mute
>45 dB
Noise power density
-75 dBm/Hz between 7.9 – 8.4 GHz, -140 dBm/Hz between 7.25 – 7.75 GHz (with external RX rejected filter)
Spurious @ PLINEAR
-65 dBc
Harmonics @ PLINEAR
-60 dBc
AM/PM conversion
<2 º/dB up to PLINEAR

About

This is an indoor 300W GaN X-band SSPA designed for commercial, government, and defense SATCOM applications. It leverages GaN technology for high power, efficiency, and robust performance in harsh environmental and operational conditions. The SSPA offers super linearity for maximum usable output power and can be customized for linearization independent of the modulation method. It includes built-in output isolator for protection against reflected power and advanced packaging and cooling techniques. Full M&C capability is provided via RS-232/RS-485/Ethernet, with monitoring of input/output power, temperature, and summary alarms. Internal self-protection mechanisms are in place for temperature, reflected power, and high input/output power. Options include redundant systems (1:1, 2:1, N:1), SNMP, indoor controller, receive reject filter (external), harmonic filter (external), air exhaust MEC interface (air cooling), and breaker panel.

Documentation

No public datasheet yet — request the datasheet / ICD from the supplier.

Source: celestia-tti.com ↗

The rest of the range from TTI Norte

All 39 products →