Mag900/901
Low power 3-axis magnetometers for surveillance applications, offering high sensitivity magnetic field measurements within a narrow noise band.
Technical specifications
- Noise band
- ≤10pTrms√Hz @ 1 Hz (After magnetic settling time)
- Measuring range
- ±60 and ±100µT
- Scaling Calibration Error
- ±0.5%
- Scaling Temperature Coefficient
- <135ppm/°C (60μT)
- Linearity Error
- <0.0033%
- Frequency Response
- DC to 10 Hz
- Bandwidth at -3dB
- >30 Hz
- Zero Field Offset
- <±100nT
- Offset Temperature Coefficient
- <1.25nT/°C
- Perming (Magnetisation Hysteresis)
- <2nT at 1 x full scale (powered)
- Orthogonality error between axes
- <1°
- Excitation Breakthrough
- <20 mV pk-pk at 8.192 kHz
- Start-up time
- 150 ms
- Magnetic settling time
- 30-60mins
- Operating temperature
- -40°C to +70°C
- Dimensions
- 29 x 25 x 100 mm
- Mass
- 25 g
- Supply voltage
- +4.5 V to 15 V
- Analogue Output
- ±3 V
- Output Impedance
- 20Ω typical
About
The Mag900 and Mag901 are low power, unpackaged 3-axis fluxgate magnetometers designed to provide high sensitivity magnetic field measurements. These devices are characterized by their narrow noise band and exceptionally low power consumption, making them particularly well-suited for perimeter surveillance applications. Their unpackaged design facilitates easy incorporation into multi-sensor systems. Key features include a noise band of ≤10pTrms√Hz @ 1Hz (after magnetic settling time) and a measuring range of ±60 and ±100µT. Beyond surveillance, these magnetometers are applicable for detecting vehicles and personnel carrying metal equipment, as well as for magnetic field measurement in remote locations and multi-sensor magnetic signature ranges. The product is also listed under ‘Space Products’ and ‘High Performance Magnetometers’ categories, indicating its suitability for demanding environments.
Documentation
- DS4550.pdf PDF source: www.bartingtondownloads.com ↗
- DS3143.pdf PDF source: www.bartingtondownloads.com ↗
- OM4550.pdf PDF source: www.bartingtondownloads.com ↗
Need the full ICD, test reports or a specific revision? Ask the supplier directly.