Mechanical Unit of Antenna Pointing System. Type 2
A two-degree-of-freedom electromechanical drive unit that rotates a satellite antenna mounting plane relative to the antenna pointing system control module in two mutually perpendicular planes.
Key figurescomparable across the catalogue
- Design life
- 14 years
- Lead time
- 6 months
Normalised to common units so this product can be compared with others in its category. The supplier's own wording is below.
As published by the supplier
- Lead time
- 6 months
- Rotation angle for each axis
- ± 25 °
- Slew rate
- 0.009-7.1 °/min
- Measurement error of the rotation angle for each axis, not exceeding
- 90 arcsec
- Developed torque for each axis, not less than
- 30 N·m
- Load inertia moment, not exceeding
- 3 kg·m2
- Self-braking torque in a de-energized state of the electric motors for each axis, not less than
- 4 N·m
- Operating temperature range
- -50 to +50 °C
- Operational life defined by hours, not less than
- 44000 hours
- Active lifetime
- 10 years
- Overall guaranteed lifetime
- 14 years
About
The Mechanical Unit of Antenna Pointing System, Type 2, provides rotation of the mounting plane for an antenna relative to the mounting plane of the antenna pointing system control module in two mutually perpendicular planes. It is a two-degree-of-freedom electromechanical drive designed for precise antenna pointing on spacecraft. Each of the two axes can rotate ±25° with a slew rate ranging from 0.009 to 7.1 °/min, and the measurement error of the rotation angle for each axis does not exceed 90 arcsec. The unit develops a torque of not less than 30 N·m per axis and can handle a load inertia moment of up to 3 kg·m2. In a de-energized state, the electric motors provide self-braking torque of not less than 4 N·m per axis. The unit is designed to operate across a temperature range of -50 to +50 °C, with an operational life of not less than 44,000 hours, an active lifetime of 10 years, and an overall guaranteed lifetime of 14 years. Estimated production/delivery time is 6 months.