VACCO V1E10689-01 ½” Bi-Directional Latch Valve-Low Pressure
A flight-qualified ½” bi-directional low-pressure latch valve with all-titanium construction, two integral microswitches, and a cycle life exceeding 150,000.
Typed specifications3 values
Discloses 2 of 8 fields engineers filter by in this category (category median 2).
- Max operating pressure (MEOP)
- 17.24 bar product page 134.45 bar
- Supply voltage
- 18–32 V product page
Each value is typed with its unit and measurement condition and cites the datasheet page it was taken from. Nothing is guessed: a field that is absent here has not been published by the manufacturer. machine-extracted ✓ checked by NewSpace Market ✓ manufacturer confirmed by the manufacturer.
As published by the supplier18 lines, in the manufacturer's own wording
- Operating pressure range
- 250 psig
- Operating temperature
- 30° to 150° F
- Proof pressure
- 1,950 psig
- Burst pressure
- 2,600 psig
- Flow
- 1.0 GPM H20
- Pressure drop (Forward Direction)
- 6 psid
- Pressure drop (Reverse Direction)
- 5 psid
- Internal leakage
- < 20.0 scch GHe
- External leakage
- <5 X 10-6 sccs GHe
- Response time
- 80 ms @ 28 VDC @ 350 psig
- Response time (2)
- 80 ms @ 28 VDC @ 0 psig
- Pull-in voltage
- 18VDC Max @ 250 psig & 150° F
- Power
- 90 Watts Max @ 32VDC & 32° F
- Operating voltage
- 18 – 32 VDC
- Dielectric strength
- 500 VAC RMS
- Inlet/outlet filter rating
- 100 Microns Absolute
- Back pressure relief
- 40-100 psid
- Cycle life
- > 150,000
About
The VACCO V1E10689-01 is a ½” low-pressure bi-directional latch valve that employs VACCO’s proven torque tube technology. It features an all-titanium construction for light weight, ensuring compatibility with stainless steel systems through transition tubing. This valve is fully flight-qualified and has extensive heritage, designed for high reliability, tight leakage, and quick response. It includes two integral microswitches and a 100-micron absolute inlet/outlet filter. This model is identical to the V1E10691 except for lower back pressure relief. Performance characteristics are based upon customer requirements.
Documentation
No public datasheet yet — request the datasheet / ICD from the supplier.